Longevity & AgingOne hip-worn sensor estimates walking energy burn using joint mechanics and a tiny neural network
Measuring how much energy a person burns while walking normally requires a lab mask system (indirect calorimetry). This engineering study asked whether one inertial sensor on the lower back (sacrum) could replace it. The authors showed that stance-leg sagittal joint power accounts for about 85% of positive whole-body joint power and correlates strongly with it (R ≈ 0.97). A small neural network predicted leg joint angles and torques from the sensor, which were converted to energy expenditure with efficiency weights and a regression scale factor. In an independent test group of 13 healthy young men on a treadmill, error was RMSE 0.69 W/kg. This is a validation of a measurement tool, not a health intervention. It was tested only in healthy adults, mostly men, on a treadmill at set speeds.